1. Before you service the valve, make sure the unit is not in a recharge cycle. Recharge will be indicated on the screen if it is currently in a cycle.
2. Bypass the unit to shut off water and depressurize.
3. Remove the hex screws from the valve, and remove the cover (#1).
4. Replace rotor/seal kit parts 2, 3, 5, 6, 7, 8, and 11. Make sure wear strip and seal are positioned correctly (#7 pictured).
5. Reassemble the top cover and hex screws.
6. Restore the water to the unit and watch for leaks.